        Back to products list

    VT Plus



Overview | Features | Models | Standard Accessories | Optional Accessories | Specifications | Get A Quote

 

Overview


 

The VT Plus is a small, lightweight, rugged unit that measures pressure, flow, volume, oxygen concentration, and barometric pressure quickly and accurately. The VT Plus is not specific to any one ventilator or gas flow device. Therefore, it can be used to maintain a large variety of respiratory products such as gas outlets, flow meters, pressure gauges, anesthesia ventilators, and vacuum systems. The high-resolution display generates extremely accurate flow, volume, and pressure waveforms. This next-generation gas flow analyzer utilizes unique bi-directional sensor technology for detecting gas flows.

Only the VT Plus has on-board trending for continuous and indefinite ventilator analysis.

The VT Plus is designed to facilitate the testing and troubleshooting of the new generation of ventilators. It is compatible with ventilators utilizing bias flow, PEEP, CPAP, pressure support, and volume support technologies.
 
"Bio-Tek really listens to what the market wants. The VT Plus is a fantastic product that has found hard-to-diagnose ventilator problems . ..no one else comes close."

Brian Sampson, Technical Support
Mediq/PRN, Pennsauken, NJ
Operational Description:
Modes of Operation
  • Manual mode for simple tests or troubleshooting
  • Computer control mode for OTIS or RT200 emulation
  • Black box mode for generating graphs and logging data to a computer
Monitor Test
This test displays 3 waveforms along with absolute, minimum, maximum, and average values for each parameter. The user can change the displayed parameter to any other parameter measured by the VT Plus. This screen can be used to study synchronized waveforms.

Flow Test
Measure the bi-directional flows of the gas in any respiratory device. This test is used specifically to verify the bias flow on a ventilator or the output of a flow meter. The unique bi-directional flow transducer in the VT Plus provides a simpler way of evaluating pulmonary function testing equipment. Two measurement ranges are provided.

Pressure Test
Choose between low, high, or airway pressure to verify the performance of pressure-controlled ventilators or gas outlets. Use the negative pressure range to measure aspirators and suction devices. Use the low pressure port to verify the proper operation of laparascopic insufflators.

Volume Test
Check the breath-to-breath volume displaced by a ventilation device or use the graph to troubleshoot sticky valves, clogged lines, or filters.

Full Test
This test obtains breath-to-breath data points simultaneously, and calculates and displays up to 17 ventilator parameters. All parameters are grouped together for efficient data analysis. From this screen, the user can perform a trend test. Simply enter one of the parameters and a percent range. If the VT Plus measures a value outside the selected range, the VT Plus will perform a full test and print out the results.

O2 Test
Graph and monitor the O2 concentration of any flow through the high flow port. Calibrate oxygen blenders and verify ventilator outputs within the range of 0 to 100%. The sensor is in a user-accessible compartment for quick and easy replacement; no need for recalibrating the whole unit.

VT Plus Graphics Program:
The VT Plus graphics software provides a simple interface for recording and playing back data calculated by the VT Plus. Most functions on the VT Plus are available using the VT Plus software.
 
Features



» Bi-directional flow measurements
» Vacuum and pressure measurements
» Liquid pressure measurement
» Operates with or without a test lung
» Completely stand-alone operation
» RS-232 and printer ports
» High resolution graphical display
» Graphics program compatible with Windows 95, 98, NT and 2000
» 18 secondary calculations
» Multiple units of measure for all parameters
» User accessible O2 concentration sensor
» Complete adapter kit
» Minimum, maximum, average, absolute, and graph for all parameters
 
Models


 


» VT Plus
 
Standard Accessories



» VT Plus Graphics Program
» External bacterial filter
» 2 of 1/8” ID PVC tubing 24” long
» 22 mm ID x 22 mm ID tubing adapter
» 22 mm OD x 15 mm ID tubing adapter
» 1/4” NPT male to 1/8” ID tubing barb fitting (nylon)
» Luer to 1/8" ID tubing barb fitting (nylon)
» Operator's manual
 
Optional Accessories



» Test lung (SMS or Siemens)
» Parabolic airway resistors: Rp 5, Rp 20, Rp 50, Rp 200, Rp 500
» RS-232 cable
» Parallel printer cable
» Tilt stand
» Soft carrying case

 

Specifications



Display
» 320 x 240 LCD with CFL backlight
» Viewing area: 3” x 4” (10.1 cm x 8.2 cm)
» Blue on white background

Oxygen Measurement
» Range: 0 - 100%
» Accuracy: + 2% FSO
» Resolution: 0.1 %O2
» Transducer location: Internal

Gas compatibility
» Air, O2, CO2, N2, N2O, mixtures or custom

Gas reference units
» ATP, STPD0, STPD21 and BTPS

Output ports
» RS-232 serial port, and parallel printer port

Power
» 90-132, 198-264 VAC, auto-switching 47-63 Hz
» Maximum over-voltage: 264 VAC

Test Parameters
Low Flow
» Range: +25 lpm
» Accuracy: 2.0% of reading or + 0.04 lpm
» Frequency response: >25 Hz
» Low flow dropout: 0.010 lpm
» Breath detect threshold: 0.10 lpm
» Maximum flow rate: 50 lpm
» Volume range: + 1 L
» Accuracy: + 3% of reading or + 2 ml
» Fittings: 15 mm OD, 1:40 conical male; 1/4” NPT ID per ASTM F-1054 Aluminum with black anodized finish
» Volume accuracy tested to 1 L

High Flow
» Range: + 300 lpm
» Accuracy: + 2.0% of reading or + 0.1 lpm
» Frequency response: >25 Hz
» High flow dropout: 1 lpm
» Breath detect threshold: 5.0 lpm
» Maximum flow rate: 500 lpm
» Volume range: + 7 L
» Accuracy: + 3% of reading or +10 ml
» Fittings: 22 mm OD, 1:40 conical male; 15 mm ID, 1:40 conical female per ASTM F-1054 Aluminum with black anodized finish
» Volume accuracy tested to 7 L

Low Pressure
» Range: + 120 cmH20
» Accuracy: + 0.75% of reading or + 0.5 cmH2O
» Frequency response: >10 Hz
» Resolution: 0.1 cmH2O
» Fittings: Luer lock, stainless steel

High Pressure
» Range: + 100 psi
» Accuracy: + 1% of reading or + 0.1 psig
» Frequency response: >10 Hz
» Resolution: 0.1 psi
» Fittings: DISS connector, stainless steel

Airway Pressure
» Range: + 120 cmH2O
» Accuracy: + 0.75% of reading or + 0.5 cmH2O
» Frequency response: >25 Hz
» Resolution: 0.1 cmH2O
» Fittings: Internally connected at the transducer distal end

Ventilator Parameter Specifications
 
Parameter Range Accuracy
Inspiratory and Expiratory Tidal Volume As specified in High/Low Flow spec As specified in High/Low Flow spec
Expiratory Minute Volume 0 - 60 L + 3% or 250 ml
Breath Rate 2 - 150 bpm + 1%
Inspiratory to Expiratory Time Ratio (I:E Ratio) 0.25 - 9.99 + 2% or 0.1 sec
Inspiratory and Expiratory Time 0.2 - 30 + 1% or 0.1 sec
Peak Inspiratory Pressure + 120 cm H2O + 3% or 1 cm H2O
Inspiratory Pause Pressure + 120 cm H2O + 3% or 1 cm H2O
Mean Airway Pressure + 80 cm H2O + 3% or .5 cm H2O
Positive End-expiratory Pressure (PEEP) -5 to 40 cm H2O + 3% or .5 cm H2O
Lung Compliance 0-150 ml/cm H2O + 5% or 5 ml/cm H2O
% Leak (pressure decay over time) 0 - 100% + 1% where initial pressure is >10 cm H2O for low differential pressure
+ 1% where initial pressure is >10 psi for high pressure port
Inspiratory Hold Time 0 - 15 sec + 3% or 0.1 sec
Expiratory Hold Time 0 - 15 sec + 3% or 0.1 sec
Peak Expiratory Flow 0 - 300 lpm + 3% or 2 lpm
Peak Inspiratory Flow 0 - 300 lpm + 3% or 2 lpm
Flow Bias 0 - 30 lpm + 2% or 0.5 lpm


Dimensions
» 10” x 10” x 5”
» (25.4 cm x 25.4 cm x 12.7 cm)

Weight
» 10 lbs. (4.53 kg)
 

 

Back to top