Overview
Put Your NIBP Monitors To The Test With
The Most Trusted Analyser On The Market.
Truly reliable performance is what more
than 2,000 registered users worldwide
have come to expect from our CuffLink
Non-Invasive Blood Pressure (NIBP)
Analyser. They’re not alone. Medical
device manufacturers around the world
also trust the CuffLink to deliver
dynamic oscillometric non-invasive blood
pressure waveforms again and again, with
1% repeatability!
How does CuffLink meet this challenge?
By offering you a quick, reliable, and
consistent way to evaluate the operation
and performance of all types of
oscillometric NIBP monitors on the
market.
The demand for repeatability is the
cornerstone upon which the CuffLink was
originally developed. We were first to
market with this new technology, and we
continue to keep pace with ongoing
advancements. For you, this means an
investment in technology that not only
meets your NIBP monitor testing needs
today, but will continue to meet future
requirements. Whether you are a
biomedical or clinical engineering
professional within a hospital, or a
manufacturer of medical devices, DNI’s
CuffLink NIBP Analyser represents a
solid investment.
Physiologically Accurate Signals
CuffLink’s NIBP waveforms are based upon
actual human physiological parameters,
so you can be sure you are simulating a
stable, "live patient" response to the
patient cuff. Plus, CuffLink further
ensures data integrity by analyzing
measurements independent of the
inflate/deflate cycle or the
interpretive algorithm used by the NIBP
monitor. You get a consistent and
repeatable source of NIBP signal,
complete with variable
systolic/diastolic values and adjustable
heart rates… just like a real patient!
The Full Spectrum
Use CuffLink to simulate the full range
of normal, hypertensive, and hypotensive
dynamic NIBP waveforms representing
typical adult, infant, and neonatal
patients. You can also generate normal,
bradycardia, and tachycardia rhythm
selections with a wide range of weak,
normal, and strong peripheral pulses.
Each selection is user-programmable. You
can easily simulate just about any
patient condition, including, for
example, mild or strenuous exercise.
With CuffLink, your NIBP monitor will
actually think there is a real patient
attached to the cuff!
Neonatal Blood Pressure Simulation
With a fast 80 millisecond rise time and
heart rates up to 240 beats per minute,
CuffLink allows you to simulate neonatal
non-invasive blood pressures as easily
as adult ones. All the cuff mandrels and
tubing adapters you will need to fit
these small neonatal cuffs are standard
CuffLink accessories.

|
» Dynamic
Oscillometric
Non-Invasive
Blood
Pressure
simulation
» Automated
static
pressure
measurements,
leakage
testing,
and
relief-valve
testing
» 5
automated
NIBP
testing
autosequences
» 5
Arrhythmia
selections
» Adult
and
Neonatal
NIBP
selections
» Adjustable
heart
rate
values
» Interfaces
directly
with
medTester
5000C
|
|
|
|
|
» Soft
Vinyl
Accessory
Pouch
» Hospital
Grade
Power
Cord
Set
» Two
Cuff
Mandrel
Assemblies
(Adult
and
Neonatal)
» Eight
Cuff
Adapters
» Pressure
Bulb
Assembly
» Operating/Service
Manual
» Optional
Accessories
|
|
|
|

» Cufflink
|
|
|
|
|
|
» Hard-Sided
Carrying Case
|
|
|
|
|
Power
» 115/230 VAC,
50 watts
average, 100
watts peak,
50/60 Hz
Analogue
Outputs
» Cuff Pressure:
0 to 300 mmHg
FS, 10 mV/mmHg
» Pulse
Pressure: 0 to
5.0 mmHg FS, 1.0
V/mmHg
Digital
Manometer
» Pressure
Range: -499.75
to 499.75 mmHg
» Measurement
Parameters:
Instantaneous
and peak
» Input
Overpressure
Limit: ± 1500
mmHg
Displayed
Graphics
» Dynamic
Real-Time NIBP
Cuff Pressure
waveform
programmed
peripheral pulse
and envelope
waveforms.
Display
» Full
Alphanumeric/Graphic
Display (LCD)
» Alphanumeric
Mode: 8 lines x
40 characters
» Graphics Mode:
64 vertical x
240 horizontal
dot matrix
backlight with
viewing angle
adjustment
Digital
Interfaces
» RS-232C/Serial:
Bi-directional.
Downloads cuff
measurement data
and controls
test features
with a
compatible
computer or via
the medTester
5000B with the
medCheck option.
» Parallel/Printer:
Centronics
compatible
» Pulse Sync: 0
to 5 VDC (TTL)
Cuff Mandrel
» Interlocking
Plastic Blocks
- Four cuff
circumferences
of 39.5 cm
(large adult),
33 cm (adult),
26.6 cm (small
adult) and 20 cm
(child). Maximum
cuff width:
15.25 cm
» Truncated
Plastic Cylinder
- Three
neonatal cuff
circumferences
of 14 cm, 10 cm,
7.6 cm. Maximum
cuff width: 7.6
cm
Pop-Off Valve
Testing
» Automatically
tests operation
of the monitor’s
relief valve
» Measurement
Parameters:
Instantaneous
and peak
pressure
» Maximum
Pressure: 499.75
mmHg
» Input
Overpressure
Limit: 1500 mmHg
System Leak
Testing
» Start
Pressure: 499.75
mmHg maximum
» Elapsed Time:
60 seconds
(fixed)
» Leak Rate
Range: 0.25 to
499.75
mmHg/minute
» Input
Overpressure
Limit: ± 1500
mmHg
Accuracy
» Systolic/Diastolic
(mean) Arterial
Pressure: Based
on pre-programmed
set points on
oscillometric
pulse envelope
» Static
Pressure: ± 1.0%
of reading, ± 1
mmHg
Cuff Adapters
» Cuff adapters
insert between
the NIBP device,
cuff, and
analyser. These
adapters are
compatible with
most current oscillometric
NIBP monitors.
-
Male/Female LUER
Locking
-
Female/Male LUER
Non-Locking
Taper
- Male/Male
Hose Barb (large
5/32 in)
- Male/Male
Hose Barb (small
1/8 in)
- Male Hose
Barb to Hose
Extension (IVAC)
-
Male/Female
Clippard
(Criutikon,
Siemens)
- Colder/CPU
(Marquette,
Protocol)
- OBAC Quick
Release (Hewlett
Packard)
Autosequences
» User can
program up to
five sequences
to test NIBP
monitors with a
specific series
of CuffLink
performance
tests. These
tests can
include:
- Static
Pressure Test
- Leak Test
- Pop-Off
Test
» Dynamic NIBP
Tests: Select up
to eight of the
Adult-Neonatal-Arrhythmia
dynamic NIBP
selections. Each
selection can be
cycled up to 99
times during the
sequence. Test
report with
results can be
printed.
Displayed
Real-Time
Parameters
» Instantaneous
Cuff Pressure:
0.0 to 300 mmHg
» Peak Cuff
Pressure: 0.0 to
500 mmHg peak
» Inflate/Deflate
Time: 0.1 to
999.9 seconds
» Inflate/Deflate
Rate: 0.1 to
999.9
mmHg/second
» Total
Measurement
Time: 0.0 to
999.9 seconds
maximum
» Selected Heart
Rate: Selected
Systolic/Diastolic
(Mean) Target
Values
» User-Programmed
Vertical and
Horizontal
Shifts
Dynamic
Non-Invasive
Blood Pressure
» Simulates the
range of normal,
hypertensive and
hypotensive
dynamic
non-invasive
blood pressures.
These represent
typical adult,
infant, and
neonatal
patients.
Generates
normal,
bradycardia, and
tachycardia
rhythm
selections with
a wide range of
user-programmable
weak, normal and
strong
peripheral pulse
amplitudes.
Compatible with
oscillometric
NIBP devices.
» Pre-programmed
Target Value
Selections
-
Systolic/diastolic
(MAP): 60/30
(40), 80/50
(62), 100/65
(75), 120/80
(90), 150/100
(115), 200/150
(165) and
255/195 (215)
-
Repeatability: ±
1% of selected
target value
» Adult
Arrhythmia
Selections
- Baseline
NIBP Target
Value: (120/80)
(NSR)
- Arterial
Fibrillation
(A-Fib)
- Premature
Arterial
Contraction
(PAC)
- Premature
Ventricular
Contraction
(PVC)
- Missed
Beat (MB)
- Aberrant
Sinus Conduction
(AS)
» Pre-programmed
Peripheral Pulse
Waveforms
- Pulse
Amplitude @ MAP:
2.0 mmHg
(typical adult
value)
- Pulse
Volume Range: 0
to 5.1 mL
- Pulse Rise
Time: 80 msec
(minimum)
- Heart
Rates: 30, 40,
60, 80, 120,
160, 200 & 240
BPM
- Heart Rate
Accuracy: ± 1.0%
of selected rate
» User
Programmable
Target Value
Shifts
- Horizontal
Axis:
Pre-programmed
target value
selections can
be shifted in
1.0 mmHg steps
over a maximum
range of ± 100
mmHg to increase
or decrease
dynamic pressure
values.
- Vertical
Axis: Relative
amplitude can be
shifted in 1%
increments over
a maximum range
from 0 to 200%
to simulate
weak, normal,
and strong
peripheral
pulses.
Dimensions
» 12.5 in W x 5
in H x 15 in L
» (31.75 cm W x
12.7 cm H x 38.1
cm L)
Weight
» 15 lb (6.82
kg)
|
|
|
|
Back to top
Back to