        BP Pump 2

 

Overview | Features | Models | Standard Accessories | Optional Accessories | Specifications | Get A Quote

 

Overview

Second Generation Technology.
The BP Pump 2 is a second-generation Non-Invasive Blood Pressure Monitor (NIBPM) Analyzer that verifies all oscillometric adult and neonatal non-invasive BP monitors quickly and accurately. The BP Pump 2 incorporates the latest technology to test today's most advanced BP monitors.

The BP Pump 2's unique, expanded feature set includes wrist-cuff simulations to accurately verify wrist-cuff monitors, internal cuffs to signal immediate problems in the cuff or monitor, and optional 5-lead synchronized ECG simulations allowing for spot checks on the ECG portion of the monitor.

Standard simulations and measurements include dynamic BP simulations, static pressure calibrations, automated leak testing, and high/low pressure relief verification.

For the mobile technician, or departments with limited bench space, the BP Pump 2 is one of the lightest and smallest units available at only 7.5 lb (3.4 kg) and 10" x 10" x 5" (25.4 x 25.4 x 12.7 cm), respectively.

Features


» Dynamic NIBPM simulations for arm and wrist-cuff monitors
» ECG and arrhythmia simulation synchronized with BP (optional)
» Internal pump: Used in high- and low-pressure release verification, leak testing and pressure sourcing
» Preset mode: Most patient conditions can be simulated using the preset mode or user-defined simulations.
» Internal adult/neonatal cuffs: Allow user to test NIBPM separate from cuff
» Respiratory artifacts including spontaneous breathing and controlled ventilation
» Arrhythmia simulations including premature arterial contractions #1 and #2, arterial fibrillation and PVCs
 

 
Models

BP Pump 2L:
» Non-invasive blood pressure monitor analyzer with internal pump.

BP Pump 2M:
» Non-invasive blood pressure monitor analyzer with high-accuracy pressure transducer.
 

 
Standard Accessories


» Detachable line cord (UK, US, Australian or European)
» Operator's manual
» Warranty card
» Bag of tubing and fittings
 
Optional Accessories


» Carrying case
» Serial cable
» Wrist-cuff mandrel
» External ECG adapter
» Printer
 
Specifications


Display
» Bright, large 4-line x 40 character alphanumeric display with backlighting

Pressure Generation
» Pressure Generator - static pressure range: 0 mmHg to +400 mmHg (~53 kPa)
» Difference between target pressure and actual pressure: < 5 mmHg

4 Respiratory Artifacts
» 3 Spontaneous Breathing
» Controlled Ventilation

3 Adult Wrist Cuff Simulations
» Normal
» Hyper
» Hypo

Pressure Source
» Generates a specified pressure from 0 to 400 mmHg. Selectable increments of 1 mmHg.

Pressure Gauge
» Measures the static pressure from 0 to 400 mmHg at the pressure port

Pressure Relief Test
» Tests the NIBPM pressure relief valve (0 to 400 mmHg). The peak pressure is displayed.

Neonate Internal Cuff Simulations
» Internal Neonate Cuff
» 4 Standard Neonate Pressures

Normal Sinus Rhythm
» (BP and ECG)
    - Healthy Heart
    - Weak Pulse
    - Mild Exercise
    - Strenuous Exercise
    - Obese Subject
    - Geriatric Subject
    - Tachycardia
    - Bradycardia

Irregular Pulse
» (BP and ECG)
    - Premature Arterial Cont #1
    - Premature Arterial Cont #2
    - Premature Ventricular Cont
    - Arterial Fib and PVCs


User Definable Simulations
» The user may specify the systolic and diastolic values along with the heart rate and pulse volume. The ranges are as follows:
    - Systolic Pressure Range: 20-250
    - Diastolic Pressure Range: 10-200
    - Heart Rate: 30-250
    - Pulse Volume: 0.1 cc-2.4 cc


Simulation Parameters Performance
» Max Pulse Volume: 2.4 cc
» Max Heart Rage:
    - 200 bpm @ 2.4 cc pulse volume
    - 250 bpm at 1.2 cc pulse volume
» Internal Neonatal Cuff Volume: 20 cc
» Internal Adult Cuff Volume (includes NN volume): 310 cc
» Heart Rate Accuracy: + 1 bpm
» Simulation Units: kPa and mmHg (user selectable)


Pressure Leak Test
» The pressure port is pressurized from 0 to 400 mmHg and keeps track of the pressure loss over time. The peak pressure and present pressure are displayed at all times. The leak rate is displayed when it is available.

Auto Sequences
» Nine auto sequences are provided for four tests and up to five simulations.

Electrical ECG
» Signals: RA, LA, RL, LL, V
» Waveform: Lead II
» Amplitude: 1 mV peak (+/- 10%)
» Connections: Optional external ECG adapter
» Physiologically synchronized with NIBP


Serial Port
» Bi-directional RS-232 port: baud rate of 9600 with no parity, one stop bit, and eight data bits.

Pressure Measurement
» Pressure Measurement Units: kPa, mmHg, cmH20, inH2O and PSI (user selectable)
» Pressure Measurement Range: 0 mmHg to +400 mmHg
» Pressure Measurement Resolution: 0.1 kPa or 1.0 mmHg
» Pressure Measurement Accuracy:TBA
» Standard Version (BP Pump 2L):
    - 0 to 300 mmHg: + 0.5% of reading + 1 mmHg
    - 301 to 400 mmHg: + 2% of reading
» High Accuracy Version (BP Pump 2M):
    - < 0.8 mmHg (0.1 kPa) throughout range

Parallel Port
» 25 pin female connector, D-subminiature style and pinouts conform to IBM "PC" printer port (unidirectional), HP and ASCII printers.

Sample Adult Arm Cuff Simulation Parameters
 
Standard Set of Blood Pressures Blood Pressure Heart Rate Pulse Volume
BP #1 120/80 (93) 80 1.2 cc
BP #2 150/100 (116) 80 1.2 cc
BP #3 200/150 (166) 80 1.2 cc
BP #4 200/150 (166) 80 1.2 cc
BP #5 0/30 (40) 80 1.2 cc
BP #6 80/50 (60) 80 1.2 cc
BP #7 100/65 (76) 80 1.2 cc


Dimensions
» 10"L x 10"D x 5"H
» (25.4 cmL x 25.4 cmD x 12.7 cmH)

Weight
» 7.5 lbs (3.4 kg)
 