   QA-90


Overview | Features | Models | Standard Accessories | Optional Accessories | Specifications | Get A Quote
 




 

 
 
Overview

 

The QA-90 represents a new generation of safety testing equipment
.  QA-90 is the only automatic safety tester that can test instruments containing modules with different classes of protection in one test run (i.e. CF and BF defibrillators).  It is simple to use.  All you need to do is select the type and class of the equipment to be tested.  When you press START, the QA-90 will execute the tests prescribed in the selected standard.

The test result can be either printed out immediately or stored internally in the unit for later use.  The QA-90 can be fully remotely controlled via ansur software.  With ansur, you can make your on test protocols, store the information on disk and export formatted data to equipment management databases.
 

 
Features


» Small size -easy to carry
»
Can operate completely standalone or by remote control with the ansur software
» Test instruments containing modules with different protection classes in one test run i.e CF and BF (defibrillator)
» Test module separation
» Differential current measurements (optional)
» 11 patient inputs (laboratory style)
» Testing against standard or user defined limits
» Automatic, stepwise and manual test modes
» Programmable power up delay time before measurements
» Integrated keypad

» Internal memory for uploading test sequences and storing typically up to 200 equipment test results
» Built-in standard A4 protocols for on site documentation
» RS-232, Centronics and Bar code interface.
 
Models

 


» QA-90
 
Standard Accessories

» Operator's manual
 
Optional Accessories


» 
 
Specifications


Specifications
Voltage
Range 0-400V true RMS
Resolution 0.1V
Accuracy DC-100 Hz 1% of full scale ±1 LSD 100 Hz-10 kHz 2% of scale ±1 LSD
Number of Tests 4 or multiple
Current Consumption
Range 1: 0-1000mA true RMS (@<250VAC) Resolution: 1mA: 0.0 to 2.0 Ω ± (2 % Accuracy: ±2% of full scale ±1 LSD No of tests: 1 or multiple
Range 2: 1-16A true RMS (@<250VAC) Resolution: 1mA:
Accuracy:
±1% of full scale ±1 LSD
No of tests: 1 or multiple
Protective Earth
  The test current is 25A or 1A, delivered from a transformer with a maximum idle voltage of 6v.  The measurement can be performed on the grounds leads or between E+ and E-
Range / Accuracy Range: 0 to 2000 mohm
Resolution: 1mA
Accuracy:
±2% of full scale or 5% of reading
No. of Tests: 1,2 or multiple
Insulating Resistance
The range of the insulating resistance may be executed between the casing and the power unit, or between patient module and power unit.
Test Voltage: 500VDC through a 130 kohm limiting resistor
No. of tests 1,2 or multiple
Range 1: 1-50 Mohm
  IResolution: 1 Mohm
  Accuracy: ±2% of full scale or ±1 LSD
Range 2: 51-200 Mohm
  Resolution: 1 Mohm
  Accuracy: ±2% of full scale or ±1 LSD
Leakage Currents
All measurements can be performed with a IEC 601.1 filter (patient equivalent), or without (flat frequency response).  The filter can be exchanged with filters covering other standards.  All measurement can be performed as true RMS measurements, or AC/DC measurements.
The following leakage currents are measured:
No. of Tests:
» Earth leakage current 4
» Enclosure leakage current 6 or multiple
» Differential current 2
» Substitute equipment current 1
» Direct current 2
» Current Fig 9.1
The following leakage currents are measured for each module:
» Patient leakage current 6
» Main on applied part leakage current 2
» Patient Auxiliary current 6
» Floating dual lead measurement of leakage currents Multiple
» Substitute patient current 1
In one test run a maximum of 11 modules with different protection classes may be tested.
Accuracy
Range 1: 0-99.99 µA
  Resolution: 0.1 µA
  Accuracy: ±2% of full scale or ±1 LSD
Range 2: 100-1000 µA
  Resolution: 1 µA
  Accuracy: ±2% of full scale or ±1 LSD
Range 3: 1.0-10.0 mA
  Resolution: 1 µA
  Accuracy: ±1% of full scale or ±1 LSD
Frequency Response
DC - 1 MHz (3dB) with a Crest factor: >2  The test voltage for the mains on applied part measurement is 110% of the line voltage, delivered through a limiting resistor of 47 kohm.

 

Back to top